Início
Quem Somos
Produtos
Baixar
Biblioteca Técnica
Contato
Interrogação
Mapa do Site
Ligações
 

Alarme & cabo Audio & Eletrônico

Belden Equivalente Cabos

Cabos coaxiais

Controle Cabos

Cabos de Fibra Óptica

Cabos Flexíveis

Instrumentação Cabos

Lan Cabos
Cabos de energia
Ferroviária Cabos

Robótica

Material Circulante Cabos
Rubber & Crane Cabos
Cabos de Segurança

Telefone Cabos

Aeroporto Cabos

Cabos Bus

Bucins

Data Cabos

Calor Detecção Cabos
High Temperature Cabos
Highway Cabos
Marine, Petróleo, Gás e Petroquímica Cabos
Cabos Especiais
Cabos espiraloidais
Termopar Cabos
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telefone Cabos

 PE/PVC Insulated Parallel Drop Wires to RUS (REA) PE-7

Aplicativo

The drop wires are designed for use in extending telephone circuits to subscriber premises by means of an aerial drop from distribution wire or cables. The shape may be in oval/dumbbell shape to aid in separation of conductors.

Normas

 

• RUS (REA) PE-7


• ASTM B227, B452 & B1

 

Construção

Condutores
Two conductors made of 0.9/1.0/1.023mm copper covered steel wires serve dually as conductor and strength members

Colagem
Bonding of the insulation to the conductors is made to assure the full conductor strength is transferred to the wire support clamps

Isolamento
Conductors are laid in a parallel configuration and covered with low density or medium density polyethylene (PE) or polyvinyl chloride (PVC)

Propriedades elétricas

Nominal Conductor Diameter

mm

0.9

1.0

1.023

Conductor Gauge Size

AWG

19

18.5

18

Conductor Size

mm2

0.636

0.785

0.827

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.kft

30/100

30/100

30/100

Dielectric Strength Conductor to Conductor(3secs)

V DC

7050

7050

7050

Nominal Insulation Thickness

mm/inch

1.02/0.039

1.02/0.039

1.02/0.039

Nominal Insulated Conductor Diameter

mm/inch

2.94/0.116

3.04/0.117

3.06/0.118

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Dimensões e Peso

Cabo Código Número de Cores Isolante
Material
Espessura nominal de isolamento
mm/inch
Nominal global Dimensões
mm/inch
Peso nominal
kg/km / lbs/kft
1.023mm Conductor, 3.06 Insulated Wire

TP7-2Y-1P18A-SS

2

PE

1.02/0.04

3.0x7.0/0.11x0.28

32/22

TP7-Y-1P18A-SS

2

PVC

1.45/0.06

3.9x7.6/0.15x0.30

49/33

1.0mm Conductor, 3.04 Insulated Wire
TP7-Y-1P18/5A-SS 2 PVC 1.02/0.04 3.9x7.4/0.15x0.29 46/31
0.9mm Conductor, 2.94 Insulated Wire
TP7-2Y-1P19A-SS 2 PE 1.02/0.04 2.9x7.7/0.11x0.30 25/17